Do not hesitate to contact us 24/7 to solve your BMS autoclave's fault. We have the same-day service opportunity for Pendik, Tuzla, Kartal, Maltepe, Kadıköy and all of Istanbul. We can make a program for Ankara, İzmir, Bursa, Antalya, Konya, Adana and other cities in the near future. Within the framework of the program to be determined for Turkey, Europe and other countries, there is Domestic and International Autoclave Technical Service, Autoclave Installation Service.

BMS Autoclave

BMS Autoclave User Manual

BMS Autoclave Error Codes

For Autoclave Error Code Solution, please review the user manual or contact us.

AL0001
AL0002
AL0003
AL0004
AL0005
AL0011
AL0012
AL0013
AL0015
AL0021
AL0022
AL0024
AL0031
AL0032
AL0034
AL0100
AL0101
AL0102
AL0110
AL0111
AL0200
AL0201
AL0202
AL0210
AL0211
AL0300
AL0301
AL0302
AL0310
AL0311
AL0400
AL0401
AL0402
AL0404
AL0405
AL0500
AL0501
AL0502
AL0504
AL0505
AL0600
AL0601
AL0700

Manual Stop
Power Failure
Door Open Error
Battery on board is dead
High Voltage Input
First Vacuum Error
Second Vacuum Error
Third Vacuum Error
Drying Vacuum Error
First Vacuum Insufficient
Second Vacuum Insufficient
Third Vacuum Insufficient
First Vacuum Cannot Be Evacuated
Second Vacuum Cannot Be Evacuated
Third Vacuum Cannot Be Evacuated
T1 Sensor Reading Error
T1 Open Circuit
T1 Short Circuit
T1 High Temperature Error
T1 Low Temperature Error
T2 Sensor Reading Error
T2 Open Circuit
T2 Short Circuit
T2 High Temperature Error
T2 Low Temperature Error
Pressure Sensor Reading Error
Pressure Sensor Open Circuit
Pressure Sensor Short Circuit
Pressure High Error
Pressure Low Error
TVP Sensor Reading Error
TVP Open Circuit
TVP Short Circuit
TVP Low Temperature Error
TVP High Temperature Error
TRS Sensor Reading Error
TRS Open Circuit
TRS Short Circuit
TRS Low Temperature Error
TRS High Temperature Error
Water in Vacuum Test Error
Water in Vacuum Test Error
T1/T2 Comparison Error

RECOMMENDATIONS FOR STERILIZATION

In order to extend the life of both the autoclave and the instruments, it is also important to follow the recommended procedures. Below you can find a list of some precautions to follow.

1. The instruments should be cleaned with suitable disinfectants immediately after use.

2. Brush the instruments to remove any residue.

3. Rinse the instruments in running water at room temperature.

4. Rinse the instruments with ultrasound.

5. Rinse the instruments in demineralized water at room temperature.

6. Dry the instruments thoroughly.

7. If you need to sterilize instruments that are not wrapped in bags, the tray should be covered with suitable tissues to ensure that each sterilized instrument dries perfectly. Follow the manufacturer's instructions for each instrument.

8. Instruments such as scissors, forceps should be slightly opened. The mirrors should be placed face down.

9. If empty containers are sterilized, place them upside down to prevent water from accumulating.

The instructions listed above show how important it is to prepare the instruments correctly for successful sterilization. Even a single instrument carrying disinfectant residue placed in the autoclave can damage the sterilization chamber and the instruments inside. In such a case, even if the alarm is not triggered, the sterilization process may be adversely affected.