COMINOX Autoclave Technical Service
Do not hesitate to contact us 24/7 to solve your COMINOX autoclave's fault. We have the same-day service opportunity for Pendik, Tuzla, Kartal, Maltepe, Kadıköy and all of Istanbul. We can make a program for Ankara, İzmir, Bursa, Antalya, Konya, Adana and other cities in the near future. Within the framework of the program to be determined for Turkey, Europe and other countries, there is Domestic and International Autoclave Technical Service, Autoclave Installation Service.
COMINOX Autoclave User Manual
COMINOX Autoclave Error Codes
For Autoclave Error Code Solution, please review the user manual or contact us.
00
01
03
04
06
07
08
09
10
11
13
14
15
16
18
21
22
23
24
Valve Error
PT1 High Temperature
Insufficient Steam
Insufficient Water
Excess Water
Door Error
Boiler Level Error
Manual Stop Error
Insufficient Vacuum
Unstable Vacuum
Probe Level Alarm
Pressure Error
High Temperature Band Alarm
Low Temperature Band Alarm
Power Failure
Discharge Alarm
Alignment Error
Pressure Sensor Error
PT1 Error
CYCLE N: Sterilization cycle for solid equipment, unpackaged only.
CYCLE S1: Sterilization cycle for solid equipment, packaged or unpackaged.
CYCLE S2: Sterilization cycle for solid instruments, porous loads and hollow loads type B, packaged or unpackaged.
CYCLE B: Sterilization cycle for solid instruments, porous loads and hollow loads type A or B, packaged or unpackaged; double packaging is also allowed.
POROUS TYPE A: Equipment with an open cavity on one side only, where the length/cavity diameter ratio is greater than or equal to 1 and less than or equal to 750 (1 ≤ L/D ≤ 750)
POROUS TYPE B: Equipment with an open cavity on one side only, where the length/cavity diameter ratio is greater than or equal to 1 and less than or equal to 5 (1 ≤ L/D ≤ 5) and where the diameter of the cavity is greater than or equal to 5 mm
Alarm codes indicate that maintenance is required or that some defect is present. If a defect is encountered during a sterilization cycle, the cycle is stopped and a 15-second beep indicates that an alarm has occurred. The description of the alarm is displayed on the screen, including the cycle and stage in which it occurred. To reset the alarm, enter the security code or insert the SterilCard 06 and press the ALARM MUTE key. After the alarm is reset and the cause is resolved if possible, start a new cycle. If the problem persists, contact SERVICE.
For your COMINOX Autoclave Technical Service request, do not hesitate to contact us 24/7 for your COMINOX Autoclave Malfunction, Maintenance, COMINOX Autoclave Repair, Installation and Remote Assistance needs.