MATACHANA Autoclave Technical Service
Do not hesitate to contact us 24/7 to solve the malfunction of your MATACHANA autoclave. We have the same-day service opportunity for Pendik, Tuzla, Kartal, Maltepe, Kadıköy and all of Istanbul. We can make a program for Ankara, İzmir, Bursa, Antalya, Konya, Adana and other cities in the near future. Within the framework of the program to be determined for Turkey, Europe and other countries, there is Domestic and International Autoclave Technical Service, Autoclave Installation Service.
MATACHANA Autoclave User Manual
MATACHANA Autoclave Error Codes
For Autoclave Error Code Solution, please review the user manual or contact us.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32
A33
A34
A35
A36
A37
A38
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A50
A51
A52
A53
A54
A55
A56
A57
A58
A59
A60
A61
Power failure
PLC communication interrupted
Room door 1 open
Room door 2 open
Chamber pressure P1 too high
Room pressure P2 too high
Pressure sensor P1 / P2 difference
Pressure P1 / temperature T1 not suitable
Pressure P1 / temperature T2 not suitable
Room temperature T1 too low
Room temperature T2 too low
Load temperature 1 1 too low
Load temperature 1 2 too low
Load temperature 2 1 too low
Load temperature 2 2 too low
Load temperature 3 1 too low
Load temperature 3 2 too low
Load temperature 4 1 too low
Load temperature 4 2 too low
[not assigned]
Room temperature T1 too high
Room temperature T2 too high
Load temperature 1 1 too high
Load temperature 1 2 too high
Load temperature 2 1 too high
Load temperature 2 2 too high high
Load temperature 3 1 too high
Load temperature 3 2 too high
Load temperature 4 1 too high
Load temperature 4 2 too high
[not assigned]
Pressure sensor P1 fault
Pressure sensor P2 fault
Pressure sensor preheating jacket fault
Temperature sensor T1 fault
Temperature sensor T2 fault
Load sensor 1 1 fault
Load sensor 1 2 fault
Load sensor 2 1 fault
Load sensor 2 2 fault
Load sensor 3 1 fault
Load sensor 3 2 fault
Load sensor 4 1 fault
Load sensor 4 2 fault
[not assigned]
Low door seal pressure
Low door 2 seal pressure
Vacuum pump fault
Stage too long
Air detector fault
L3 Alarm
Incorrect hardware configuration
Emergency stop
Filter temperature 1 too low
Filter temperature 2 too low
Filter temperature 1 too high
Filter temperature 2 too high
Filter Sterilization temperature 1 sensor fault
Filter Sterilization temperature 2 sensor fault
External VHP Generator fault
In MATACHANA autoclaves, 3 types of error codes are received: A, W, E.
A = ALARMS
Alarms are caused by a fault in the autoclave that prevents the cycle from being completed successfully. This type of message generates an automatic recovery cycle, which means that the ongoing cycle will be cancelled. When running the reset program, the display will show the control phase of the process reset (RST). The sterilizer will then run the steps in the process that are absolutely necessary to reach the end of the cycle and will open door 1 to ensure that the load is safely removed.
W = WARNINGS
Warnings are caused by an autoclave fault. However, they do not cause the ongoing cycle to be reset. The cycle will continue until the end, receive the error-free cycle end indicator (except for Warnings W23, W32, W33, W47 and W48) and allow the load to be unloaded. However, it will not be possible to start a new cycle if the condition that generated the Warning is still present.
E = ERRORS
Errors occur when the autoclave user performs an inappropriate action; for example, trying to open the door in a situation that is not allowed for safety reasons. Such a message does not cause the ongoing cycle to reset.
For your MATACHANA Autoclave Technical Service request, do not hesitate to contact us 24/7 for your MATACHANA Autoclave Malfunction, Maintenance, MATACHANA Autoclave Repair, Installation and Remote Assistance needs.