STERN WEBER Autoclave Technical Service

Do not hesitate to contact us 24/7 to solve your STERN WEBER autoclave's fault. We have the same-day service opportunity for Pendik, Tuzla, Kartal, Maltepe, Kadıköy and all of Istanbul. We can make a program for Ankara, İzmir, Bursa, Antalya, Konya, Adana and other cities in the near future. Within the framework of the program to be determined for Turkey, Europe and other countries, there is Domestic and International Autoclave Technical Service, Autoclave Installation Service.

STERN WEBER Autoclave

STERN WEBER Autoclave User Manual

STERN WEBER Autoclave Error Codes

For Autoclave Error Code Solution, please review the user manual or contact us.

E000
E001
E002
E003
E004
E007
E008
E009
E010
E020
E021
E022
E030
E031
E042
E050
E051
E052
E060
E061
E070
E126
E130
E141
E900
E901
E902
E998
E999
A032
A040
A042
A101
A102
A103
A105
A111
A112
A113
A115
A116
A117
A120
A121
A122
A126
A131
A132
A133
A134
A135
A136
A140
A145
A146
A147
A201
A202
A250
A251
A252
A253
A254
A255
A256
A257
A258
A260
A261
A262
A353
A356
A360
A362
H150
H160
H400
H401
H402
H403
H404
H405
H406
H410
H411
H990
H991
H993

POWER FAILURE
OVERVOLTAGE
INSUFFICIENT WATER QUALITY
POOR QUALITY WATER
LINE FREQUENCY ERROR
FAN PROBLEM
WATER CONDUCTIVITY ERROR
WATER CONDUCTIVITY ERROR
DOOR OPEN
DOOR LOCK ERROR
DOOR LOCK ERROR
DOOR LOCK ERROR
WATER LEVEL ERROR
WATER LEVEL ERROR
WATER LEVEL ERROR
RUN VACUUM TEST
RUN HELIX TEST
RUN VACUUM+HELIX TEST
ETHERNET CONFIGURATION ERROR
WI-FI CONFIGURATION ERROR
CLOSE DOOR
CLOUD SOFTWARE UPDATE IN PROGRESS
CYCLE DISABLED LEFT
CLOUD SOFTWARE VERSION ERROR
VACUUM TEST FAILED
VACUUM TEST FAILED
VACUUM TEST FAILED
REMOTE SERVICE ACTIVE
MANUAL INTERRUPTION
LEVEL SENSOR PROBLEM
WATER INLET FAILURE
WATER FILLING MAXIMUM
PT1 BROKEN (STERILIZATION CHAMBER)
PT2 BROKEN (STEAM GENERATOR)
PT3 BROKEN (HEATING ELEMENT)
PT5 BROKEN
PT1 SHORT CIRCUIT (STERILIZATION CHAMBER)
PT2 SHORT CIRCUIT (STEAM GENERATOR)
PT3 SHORT CIRCUIT (HEATING ELEMENT)
PT5 SHORT CIRCUIT
ADC ERROR ON PCB
DOOR MOTOR OVER CURRENT
PROCESSING CARD ERROR3
PROCESSING CARD ERROR
PROCESSING CARD ERROR
WI-FI MODULE ERROR
SOLENOID VALVE 1 FAULTY
SOLENOID VALVE 2 FAULTY
SOLENOID VALVE 3 FAULTY
SOLENOID VALVE 4 FAULTY
SOLENOID VALVE 5 FAULTY
SOLENOID VALVE 6 FAULTY
CLOUD FW UPDATE ERROR
INCORRECT CURRENT DRAWING
SOLENOID VALVE DRIVER ERROR
DOOR MOTOR DRIVER ERROR
STEAM GENERATOR RESISTOR OPEN CIRCUIT
HEATING BAND OPEN CIRCUIT
1PV TIMEOUT
ATM1 UP STROKE
1PP UP STROKE TIMEOUT
2PV TIMEOUT
ATM2 UP STROKE TIMEOUT
2PP UP STROKE TIMEOUT
3PV TIMEOUT
ATM3 UP STROKE TIMEOUT
3PP UP STROKE TIMEOUT
ATM3 DOWN STROKE TIMEOUT
PRESSURE LEVELING TIMEOUT
PRESSURE UP STROKE TIMEOUT
ATM1 DOWN STROKE TIMEOUT
ATM2 DOWN STROKE TIMEOUT
SPD PRESSURE STAGE
PRESSURE DOWN TIMEOUT
PRESSURE SENSOR OPEN CIRCUIT
SENSOR SHORT CIRCUIT
PCONV/T RATIO NOT BALANCED
T/P CONVERSION RATIO NOT BALANCED
TEMPERATURE ABOVE MAX LIMIT
TEMPERATURE BELOW MIN LIMIT
TEMPERATURE CHANGING ABOVE LIMIT
PRESSURE ABOVE MAX LIMIT
PRESSURE BELOW MINIMUM LIMIT (STERILIZATION PHASE)
TIME MEASUREMENT ERROR
STERILIZATION TIME ERROR
OVERPRESSURE
OVERHEATING (STERILIZATION CHAMBER, PT1)
OVERHEATING (LAYER RESISTANCE, PT3) PT3)

There are 4 types of error codes in STERN WEBER autoclaves: E, A, H and S.

E = ERROR
Errors that occur due to a reason other than the user or the device.
These problems can usually be solved by the user.
Warning codes between E000 and E999 occur.

A = ALARM
First-degree failures
These problems can usually be solved by a device technician.
Warning codes between A000 and A999 occur.

H = DANGER
Second-degree failures
In these problems, the device must be examined in detail and taken into maintenance.
Warning codes between H000 and H999 occur.

S = SYSTEM ERROR
These warnings are received in cases of failures in the electronic system.
It can be solved by turning the autoclave device off and on, resetting it.
Warning codes between S000 and SA999 occur.

For your STERN WEBER Autoclave Technical Service requests, STERN WEBER Autoclave Malfunction, Maintenance, STERN WEBER Autoclave Repair, Installation and Remote Assistance needs, please do not hesitate to contact us 24/7.