WOSON Autoclave Technical Service
Do not hesitate to contact us 24/7 to solve your WOSON autoclave's fault. We have the same-day service opportunity for Pendik, Tuzla, Kartal, Maltepe, Kadıköy and all of Istanbul. We can make a program for Ankara, İzmir, Bursa, Antalya, Konya, Adana and other cities in the near future. Within the framework of the program to be determined for Turkey, Europe and other countries, there is Domestic and International Autoclave Technical Service, Autoclave Installation Service.
WOSON Autoclave User Manual
WOSON Autoclave Error Codes
For Autoclave Error Code Solution, please review the user manual or contact us.
Er01
Er02
Er03
Er04
Er05
Er06
Er07
Er08
Er09
Er10
Er12
Er14
Er27
Er71
Er72
Er98
Er99
Steam generator overtemperature
Heating ring overtemperature
Boiler overtemperature
Failure to maintain temperature and pressure
Pressure release error
Door opened during cycle
Excessive run time
Overpressure
In-room sensor temperature too high or too low (only for dual sensors)
Temperature and pressure do not match
Vacuum fault
Boiler in-room sensor temperature. varies too much (only for dual sensors)
Air pressure low (due to high altitude)
Pressure sensor output low
Pressure sensor output high
Power outage during cycle
Forced exit program
Some Points to Note When Using WOSON Autoclave:
The user is responsible for the correct operation and maintenance of WOSON Autoclave according to the instructions listed in the manual.
Use the tray holder to remove the tray from the chamber at the end of sterilization.
Do not open the chamber door during sterilization programs.
Do not put your hands or face close to the water tank cover while the autoclave is operating.
Do not pour water or other liquids onto the autoclave.
Do not fill the water tank with caustic liquid.
Do not fill the chamber with caustic substances.
Use only high-quality distilled water.
Before inspecting or maintaining the machine, disconnect the power cord.
In case of transportation, completely empty both water tanks, wait for the sterilization chamber to cool down, and preferably use the original packaging.
When the temperature exceeds 40°C, the materials subject to sterilization should be removed with special tools.
In case of transportation, the autoclave should be carried by two people in case of overturning.
Do not close the water tank cover during use.
For your WOSON Autoclave Technical Service request, WOSON Autoclave Malfunction, Maintenance, WOSON Autoclave Repair, Installation and Remote Assistance needs, do not hesitate to contact us 24/7.